This user guide provides instructions for preparing, packing, and maintaining the Pelican BioThermal CoolGuard Advance Series 20M shipping system.
The Pelican BioThermal CoolGuard Advance Series 20M is a high-performance, single-use shipping system designed to protect temperature-sensitive payloads. It utilizes advanced insulation and phase change materials (PCM) to ensure consistent thermal protection during transit. The system is pre-qualified for various ambient profiles and features a standardized assembly process to minimize errors.
This guide covers the complete lifecycle of the shipping system, including conditioning the PCM BRICS using freezer or dry ice methods, assembling the system with Vacuum Insulation Panels (VIPs), loading the payload, and inspecting the VIPs for vacuum integrity. It also details the recycling procedures for the various components, including corrugated cardboard, expanded polystyrene, and the inorganic salt solution PCM.
They must be conditioned for a minimum of 24 hours.
The grouping carton must condition for at least 48 hours.
The payload must be conditioned at -18°C or below.