Pelican BioThermal CoolGuard Advance Series 20M User Guide
The Pelican BioThermal CoolGuard Advance Series 20M is a high-performance, single-use shipping system designed to protect temperature-sensitive payloads. It utilizes advanced insulation and phase change materials (PCM) to ensure consistent thermal protection during transit. The system is pre-qualified for various ambient profiles and features a standardized assembly process to minimize errors.
This guide covers the complete lifecycle of the shipping system, including conditioning the PCM BRICS using freezer or dry ice methods, assembling the system with Vacuum Insulation Panels (VIPs), loading the payload, and inspecting the VIPs for vacuum integrity. It also details the recycling procedures for the various components, including corrugated cardboard, expanded polystyrene, and the inorganic salt solution PCM.
Covers: Product Overview · System Diagram · CoolGuard Advance Benefits · Preparing your CoolGuard BRICS · Packing your CoolGuard Advance System · Caring for your CoolGuard Advance System
Latest Pelican BioThermal manuals
Pelican BioThermal CoolGuard Advance Series 20M User Guide
User Manual 8 pages · 818 KB · ENThis user guide provides instructions for preparing, packing, and maintaining the Pelican BioThermal CoolGuard Advance Series 20M shipping system.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Pelican BioThermal manuals
How long must PCM BRICS be conditioned in a freezer set to -40°C?
They must be conditioned for a minimum of 24 hours.
From: Pelican BioThermal CoolGuard Advance Series 20M User Guide
How many hours are required to condition PCM BRICS using pelletized dry ice?
The grouping carton must condition for at least 48 hours.
From: Pelican BioThermal CoolGuard Advance Series 20M User Guide