About this manual

The FIREBIRD SI Fusion System is a temporary, multiple-component system with non-sterile instruments and sterile cannulated screws of various lengths and diameters with multiple fenestrations. The screws are made from medical-grade titanium alloy (Ti-6Al-4V ELI); 11mm and 12mm screws are 3D printed with a mid-shaft porous region.

Indications include fixation of sacroiliac joint disruptions and sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis. The document also lists contraindications, potential adverse events, warnings and precautions, MRI compatibility information, and cleaning instructions.

What's inside

  • Description
  • Indications for Use
  • Contraindications
  • Potential Adverse Events
  • Warnings and Precautions
  • MRI Compatibility Information
  • Cleaning

Specifications

Screw materialMedical-grade titanium alloy (Ti-6Al-4V ELI)
Implant diameters11mm and 12mm
Implant lengths25mm to 70mm
11mm implant featuresTapered proximal end and dual-pitch threads
12mm implant featuresSingle pitch thread form on proximal and distal ends
3D-printed screws11mm and 12mm screws with mid-shaft porous region
Porous regionOpen macroscopic 3D pores with microscopic roughened surface
Single-use componentsSteinmann Pins, Drills, and Packing Tubes are single use

Frequently asked questions

What material are the FIREBIRD SI Screws made from?

They are constructed from medical-grade titanium alloy (Ti-6Al-4V ELI).

What is the FIREBIRD SI Fusion System indicated for?

It is intended for fixation of sacroiliac joint disruptions and sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.

Is the FIREBIRD SI Fusion System MRI compatible?

It has not been evaluated for safety and compatibility in the MR environment, and its safety is unknown.

Can the implants be reused?

No; all implants are intended for single use only and used implants should be discarded.