Installation and operation manual for Neptune TRI-8, TRI-12, and TRI-20 UV disinfection systems for potable water treatment.
This manual covers installation, operation, and maintenance requirements for Neptune U.V. Disinfection Systems, models TRI-8, TRI-12, and TRI-20. It provides safety instructions, step-by-step installation guidance, and operating procedures for the ultraviolet disinfection unit.
The Triton series units use a UV germicidal lamp housed in a quartz sleeve within a stainless steel pressure chamber to reduce waterborne pathogenic bacteria by over 99%. The system includes an ATS-280CB UV Lamp Detector and Timer circuit board with LED status indicators and alarm features.
| UV lamp wavelength | 254 nanometer |
|---|---|
| UV dosage | 30,000 microwatt second per square centimeter |
| Maximum operating pressure | 100 psi |
| UV lamp life | approximately 9,000 hours |
| Chamber material | 304 Stainless Steel |
| Bacteria reduction | in excess of 99% |
The UV lamp should be replaced annually to ensure continuous water treatment.
It indicates the UV system is operational and the system check is OK.
The operating pressure should not exceed 100 psi.