This is an operating manual that introduces the use and installation methods of the NEPTUNE JG and JD series mixers.
This document serves as the operating and instruction manual for Neptune Chemical Pump Company's Series JG Gear Drive, Series JD Direct Drive, Series JGR/JDR Angle Riser Mount, and Series JGF/JDF Flange Mount mixers. It provides essential safety warnings, such as the requirement for lockouts before servicing, and outlines proper installation procedures including shaft and propeller assembly.
The manual specifies using LUBRIPLATE 1200-2 Grease and recommends changing it annually.
The shaft should be angled 5° to 15° off the vertical wall of the tank.
The mixer must be turned off when the liquid level is one propeller diameter above the lower propeller.