Specifications, features, dimensions, venting, and warranty information for Napoleon 9600 Series (WPV-N) gas furnaces.
This leaflet covers the Napoleon 9600 Series (WPV-N) high-efficiency gas furnaces, including model WPV060T3AA-N, with model breakdowns, airflow tables, cabinet dimensions, venting equivalents, and warranty terms.
It also lists approved venting materials, blower and motor information, AC tonnage ranges, and registered and unregistered warranty coverage.
| AFUE | 96.0% |
|---|---|
| High fire input (series) | 40,000 to 120,000 BTU/HR |
| Low fire input (series) | 24,000 to 72,000 BTU/HR |
| Motor type | Variable |
| Motor size (series) | 1/3 HP to 1 HP |
| Blower size (series) | 112-6RDD to 112-10RDD |
| Short radius elbow equivalent | 7 ft (2.13 m) |
| Standard radius elbow equivalent | 5 ft (1.52 m) |
| Long radius elbow equivalent | 3 ft (0.91 m) |
| 45 degree elbow equivalent | 2.5 ft (0.76 m) |
| Heat exchanger warranty (registered) | Lifetime for original registered owner |
| Remaining parts warranty (registered) | 10 years |
| Heat exchanger warranty (not registered) | 20 years (pro rated) |
| Remaining parts warranty (not registered) | 5 years |
The listed 9600 Series models have an AFUE of 96.0%.
The heat exchanger is warranted for the original registered owner's lifetime and all remaining parts for 10 years, for an owner-occupied primary single family residence.
Approved materials include Schedule 40 PVC, PVC-DWV, Schedule 40 CPVC, PVC primer and solvent cement, and PPE ULC S636 manufactured by M&G Duravent.
The airflow table lists 36,000 BTU/HR among the low fire inputs for the series.