The fireplace is manufactured by Wolf Steel Ltd. and has the model number FRENCH PG. 45 W415-2837 / B. It complies with CSA/OMNI/INTERTEK safety standards and is EPA-qualified.
This document is the installation and operation manual for the Napoleon S25 wood stove. It provides safety information, installation requirements, and operating instructions for the appliance.
The manual includes warnings about hot surfaces and glass, prohibited fuels, chimney cleaning, and ash disposal.
| Minimum outside air for wood stoves | 14 sq in (90.3 sq cm) |
|---|---|
| Minimum front clearance to combustibles | 48 in (121.9 cm) |
| Maximum stove top temperature | 700°F (371°C) |
The appliance is designed to burn natural wood only; do not burn trash, garbage, treated wood, or the other materials listed.
Clean the chimney a minimum of twice a year and as required.
Dispose of ashes in a metal container with a tight lid on a non-combustible surface until they are completely cool.
No. Hot glass will cause burns, so do not touch the glass until it has cooled and never allow children to touch it.