User manual for the Mutian ZKS-III three-phase reversible thyristor DC motor speed controller, covering specifications, wiring, adjustments and fault handling.
This manual describes the ZKS-III series four-quadrant thyristor drive, a domestically produced successor developed after study of the Siemens SIMOREG-K and MODULPAC-C. It is used as a drive unit in wire and cable, petrochemical, metallurgical machinery, gantry milling machines and other industrial control applications.
The manual covers the operating environment, main technical parameters, basic performance and the dual closed-loop control principle (current inner loop with speed/voltage outer loop), plus usage instructions, main board terminal functions, potentiometer adjustments (W1–W16) and simple fault handling via the indicator LEDs. It ends with a list of other products from the manufacturer, Shanghai Mutian Mechanical & Electrical Equipment Co., Ltd. This manual is written in Chinese.
| Input voltage | 3AC380V |
|---|---|
| Output voltage / current (±440V version) | DC±440V, 100A–1000A |
| Output voltage / current (±220V version) | DC±220V, 100A–2000A |
| Static accuracy | 1/1000 |
| Dynamic speed drop | △n/n < 2% |
| Dynamic adjustment time | △t < 0.5S |
| Steady-state speed drift | < ±0.5% within 24 h |
| Speed range | 1:25 |
| Overload capacity | 1.5× for 3 min; 2.5× for 30 s |
| Speed accuracy (speed feedback) | ±0.3% of rated speed |
| Speed accuracy (voltage feedback) | ±1.5% of rated speed |
| Field output | DC200V / DC340V |
| Operating temperature | -5℃ to 40℃ |
| Altitude / humidity | < 1000 m; humidity < 85% |
No. L1, L2 and L3 are the three-phase AC 380V main circuit inputs and there is no phase sequence requirement.
The unit must be installed vertically to allow air convection and heat dissipation, with clearances above and below meeting the installation requirements.
Check that the housing is undamaged, that cables and wiring are not loose, and that external wiring is correct; read the manual carefully before powering on.
The factory default is armature voltage feedback with the J1 shorting link, which is used to choose between tachometer feedback and voltage feedback.