Mutian ZKS-III Three-Phase Reversible DC Motor Speed Controller User Manual

User manual for the Mutian ZKS-III three-phase reversible thyristor DC motor speed controller, covering specifications, wiring, adjustments and fault handling.


Mutian ZKS-III Three-Phase Reversible DC Motor Speed Controller User Manual - cover page
Brand
上海沐天机电设备有限公司
Category
Motor
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
226 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
217F7F12768AD0B4EEF8518CA9920AB3

About this manual

This manual describes the ZKS-III series four-quadrant thyristor drive, a domestically produced successor developed after study of the Siemens SIMOREG-K and MODULPAC-C. It is used as a drive unit in wire and cable, petrochemical, metallurgical machinery, gantry milling machines and other industrial control applications.

The manual covers the operating environment, main technical parameters, basic performance and the dual closed-loop control principle (current inner loop with speed/voltage outer loop), plus usage instructions, main board terminal functions, potentiometer adjustments (W1–W16) and simple fault handling via the indicator LEDs. It ends with a list of other products from the manufacturer, Shanghai Mutian Mechanical & Electrical Equipment Co., Ltd. This manual is written in Chinese.

What's inside

  • 概述 (Overview)
  • 使用环境 (Operating Environment)
  • 主要技术参数 (Main Technical Parameters)
  • 基本性能 (Basic Performance)
  • 基本原理 (Basic Principle)
  • 使用方法与简单故障处理 (Usage and Simple Fault Handling)
  • 主板接线端子功能 (Main Board Terminal Functions)
  • 主要运行参数的调整 (Adjustment of Main Operating Parameters)
  • 其它产品介绍 (Other Products)

Specifications

Input voltage3AC380V
Output voltage / current (±440V version)DC±440V, 100A–1000A
Output voltage / current (±220V version)DC±220V, 100A–2000A
Static accuracy1/1000
Dynamic speed drop△n/n < 2%
Dynamic adjustment time△t < 0.5S
Steady-state speed drift< ±0.5% within 24 h
Speed range1:25
Overload capacity1.5× for 3 min; 2.5× for 30 s
Speed accuracy (speed feedback)±0.3% of rated speed
Speed accuracy (voltage feedback)±1.5% of rated speed
Field outputDC200V / DC340V
Operating temperature-5℃ to 40℃
Altitude / humidity< 1000 m; humidity < 85%

Frequently asked questions

Does the three-phase mains input require a specific phase sequence?

No. L1, L2 and L3 are the three-phase AC 380V main circuit inputs and there is no phase sequence requirement.

How should the ZKS-III be installed?

The unit must be installed vertically to allow air convection and heat dissipation, with clearances above and below meeting the installation requirements.

What should be checked before using the device?

Check that the housing is undamaged, that cables and wiring are not loose, and that external wiring is correct; read the manual carefully before powering on.

How is speed feedback selected between tachometer and voltage feedback?

The factory default is armature voltage feedback with the J1 shorting link, which is used to choose between tachometer feedback and voltage feedback.