Manual for MTH T31 Series horizontal close coupled and flexible coupled regenerative turbine pumps, covering inspection, storage, installation, operation…
This manual covers the T31 Series of horizontal close coupled and flexible coupled regenerative turbine pumps. It provides general instructions for inspection of equipment, storage, placing stored pumps into service, and application considerations including electrical wiring, construction materials, valves, priming, and NPSH.
The document also includes guidance on recommended spare parts and detailed procedures for handling pumps that have been in storage, including torque limits and steps to break loose a stuck impeller.
| Electrical terminal torque | 13-16 inch-lbs |
|---|---|
| Maximum shaft torque for breaking loose | 50 foot pounds |
| Storage period requiring corrosion inhibitor | Beyond 30 days |
A gate, ball, butterfly, or other full port valve should be used. A swing check valve is also recommended in the suction line.
Do not apply further force. Refer to the Disassembly/Reassembly Instructions in Section 5 to determine the cause of the problem.
For storage beyond 30 days, a corrosion inhibiting protective fluid should be added to the internal pump cavities.