This document is the E41 series turbine pump maintenance manual
This Spanish-language manual covers the E41•T41 Series regenerative turbine pumps. It gives general instructions for receiving and inspecting equipment, storage, and placing stored pumps back into service, including freeing an impeller that does not turn.
It also addresses electrical wiring, valve use and startup, NPSH, noise, freezing protection, and recommended spare parts for critical, important, and general service. This manual is written in Spanish.
| Pump type | Regenerative turbine pump |
|---|---|
| Maximum shaft torque during freeing procedure | 50 ft-lb |
| Storage protection duration | More than 30 days requires a protective liquid |
| NPSH measurement unit | Feet of pumped liquid |
Fill the pump with water and try again over several hours; if it still does not turn, refer to the disassembly/reassembly instructions.
Keep the discharge valve open as far as possible and the suction valve open; never start the pump with the discharge valve closed.
For critical service, the manual recommends a two-sided installation with two identical pumps in parallel.
It is the net positive suction head above the vapor pressure of the pumped liquid at the pump centerline, expressed in feet of pumped liquid.