Service manual for Moyno 500 pumps covering design, installation, operation, troubleshooting, maintenance and parts.
The Moyno 500 Pumps 300 Series service manual provides detailed information for models 331, 332, 333, 344, 356 and 367. It includes design features, installation guidelines, operating instructions, troubleshooting tips, maintenance procedures, and complete parts lists.
The manual also contains repair and conversion kit numbers, elastomer temperature limits, suction and discharge port specifications, and warranty registration instructions, helping technicians service the pumps efficiently.
| Maximum Speed | 1750 rpm |
|---|---|
| Elastomer Temperature Limit (NBR) | 10°‑160°F |
| Elastomer Temperature Limit (EPDM) | 10°‑210°F |
| Elastomer Temperature Limit (FPM) | 10°‑240°F |
The pumps are rated for a maximum speed of 1750 rpm.
NBR elastomer can be used from 10°F up to 160°F.
When mounted vertically, keep the bearings above the seals to prevent possible seal leakage into the bearings.