Installation and operation manual for Moffat C6 (600 mm) and C9 (900 mm) gas cooktops, including gas supply, installation, operation, cleaning and…
The Moffat C6 (600 mm) and C9 (900 mm) gas cooktops are part of the Cobra Series. This installation and operation manual covers model numbers, gas supply requirements and connection, dimensions, installation requirements, commissioning and the operation guide for open burners and griddles.
It also includes daily and weekly cleaning, periodic maintenance, the gas conversion procedure and gas specifications. Safety instructions warn that installation, adjustment, alteration, service or maintenance must be carried out correctly and that installation should comply with local gas and health and safety requirements.
| Model widths | C6: 600 mm; C9: 900 mm |
|---|---|
| Gas connection | ¾” BSP male thread (all models) |
| Input rate (open burner and griddle) | Open burner: 22 MJ/hr; griddle (each 300 mm section): 20 MJ/hr (N.H.G.C.) |
| Supply pressure (Australia/New Zealand) | 1.13 – 3.40 kPa |
| Burner operating pressure (Australia/New Zealand) | 1.0 kPa |
| Griddle widths | 300 mm, 600 mm; C9 also has a 900 mm option |
The manual covers C6 (600 mm) and C9 (900 mm) gas cooktops, with model variants for open burners and griddles.
The connection is a ¾” BSP male thread for all models.
Installation must be carried out by qualified service persons only.
All griddle options are fitted with pilot, flame failure and piezo ignition as standard.