The MOBOTIX MX-DoorMaster (order designation MX-Door2-INT, which includes two additional frames, a cavity wall socket and mounting supply) is a security door opener with access code storage. It controls door openers via encrypted MxBus communication and provides a doorbell for indoor installation, including a backup power supply for the bell features and the door opener.

This quick install document refers to the IP Video Door Station System Manual Part 1, Section 2.5, for mounting the module and for connection variants such as relay or Mediator operation. It also covers charging the NiMH battery pack without interruption for at least 12 hours after installation over the MxBus two-wire connection, the door openers that can be attached directly or via an external power supply, replacing the battery pack or the module, and the key, LED and audio signaling states. Notes state that the device is intended for indoor use only and give the battery pack order number and the maximum torque for the cover screw.

What's inside

  • Installing the MX-DoorMaster
  • Charging the Battery Pack after Installing
  • Supported Door Openers
  • Replacing the Battery Pack
  • Replacing the MX-DoorMaster
  • Operation: Keys and Signaling
  • Adjust Volume
  • Adjust Doorbell Sound
  • General Signals
  • Special/Error States

Specifications

Directly connected door openers6 to 12 V AC, min. 16 Ω internal resistance
Door openers via external power supply (relay operation)up to 24 V AC/DC, max. 1 A
Battery pack charging after installationat least 12 hours without interruption
MxBus cableYSTY 0.8 mm, max. length 50 m
Backup power supply duration on power failureup to 60 hours for keypad and door opener
Maximum torque for the cover screw0.4 Nm
Battery pack order numberMX-Door1-BAT

Frequently asked questions

How long do I have to charge the MX-DoorMaster battery pack after installing?

The battery pack must be charged without interruption for at least 12 hours. The IP Video Door Station and its PoE power supply charge the module automatically via the MxBus two-wire connection, and the door opener should not be used during this time except for a short functional test.

Which door openers can be attached to the MX-DoorMaster?

Standard door openers with 6 to 12 V AC and at least 16 Ω internal resistance can be attached directly and are powered by the integrated battery pack. Door openers with up to 24 V AC/DC (max. 1 A) can be connected using an external power supply in relay operation or a self-locking door lock (Mediator).

Can the MX-DoorMaster be used outdoors?

No. The device is intended for indoor use only and must not be used outdoors.

How do I open the door with the MX-DoorMaster?

Press the door opener key for 3 seconds; the LED flashes 3 times in 3 seconds and then twice, with one beep per second followed by two beeps as acknowledgement.