This manual covers the operation, installation, wiring, settings, and troubleshooting for the Mik U-MIK-LDG/LDGC-SUP-CN9 electromagnetic flowmeter.
This user manual provides comprehensive instructions for the Mik U-MIK-LDG/LDGC-SUP-CN9 electromagnetic flowmeter. It details the working principles of the device, including the Faraday electromagnetic induction law, and describes the main components such as the sensor and converter. The guide covers safety guidelines, installation requirements for both pipe-mounted and insertable models, and electrical connection procedures. This manual is written in Chinese.
| Measurement Principle | Faraday electromagnetic induction theorem |
|---|---|
| Converter Protection Rating | IP65 |
| Sensor Diameter Range | DN10~DN2000 |
| Maximum Measurement Error | ±0.5% of reading (velocity ≥1m/s) |
| Power Supply Voltage | 85VAC~245VAC, 50/60Hz |
| Output Current Range | 4~20mA |
| Minimum Conductivity (Water) | 20μS/cm |
The minimum conductivity for water is 20μS/cm, though actual measurement should be greater than 30μS/cm.
The upstream straight pipe length should be greater than or equal to 15 times the pipe diameter (15D).
The maximum measurement error is ±0.5% of the reading.