This manual details the software operation, parameter settings, calibration procedures, and output adjustment for the MIK YC180 digital remote pressure gauge.
The MIK YC180 is a digital remote pressure gauge featuring a two-wire working mode, support for multiple pressure units, and a 0.36-inch four-digit LED display. It allows for digital filtering coefficient adjustment, three-key parameter setting, and calibration. The device supports input of 8 segments (9 points) of linear correction and offers on-site zero-point correction functionality. It is designed with high integration, anti-interference design, and software/hardware watchdogs. This manual is written in Chinese.
| Power Supply | DC12~36V (Recommended DC24V) |
|---|---|
| Signal Range | ±5mV, ±7mV, ±8mV, ±10mV, ±13mV, ±20mV, ±40mV, ±80mV |
| Sampling Rate | 10 times/second |
| Display Range | -1999~1999 |
| Output Accuracy | ±0.5%, ±0.25% |
| Temperature Drift | <40ppm/℃ |
| Operating Temperature | -20~+80℃ |
| Humidity | <85%RH |
| Power Consumption | Less than 0.3W (including LED display) |
The recommended power supply voltage is DC24V, with an acceptable range of DC12 to 36V.
The device supports eight signal ranges: ±5mV, ±7mV, ±8mV, ±10mV, ±13mV, ±20mV, ±40mV, and ±80mV.
The number of calibration points can be set between 2 and 9.