About this manual

This Use and Maintenance Manual from M.G.M. motori elettrici S.p.A. covers the BA H 225 series of asynchronous three-phase totally enclosed fan cooled brake motors. It explains the field of application, CE marking, general safety information, motor nameplate fields, centre of gravity, receipt and storage, and installation.

The manual states that nameplate performance is guaranteed from -15 °C to +40 °C at altitudes below 1000 m, that the brake engages on power supply failure, and that installation and maintenance must be carried out by qualified personnel with the motor disconnected from the supply. It also gives checks for insulation resistance, lifting, alignment and protection degree.

What's inside

  • Field of application
  • CE Marking
  • General safety information
  • Motor identification nameplate
  • Centre of gravity
  • Receipt and Storage
  • Installation

Specifications

Motor typeAsynchronous three-phase totally enclosed fan cooled brake motors
Ambient temperature range-15 °C to +40 °C
Maximum installation altitudeBelow 1000 m above sea level
Earth insulation resistanceNot less than 25 MΩ
Insulation resistance test instrument500 V DC Megger
Lifting eye threadM16
Motor balancingFitted half key (60034-14)
CE directives2006/95/CE Low voltage; 2004/108/CE Electromagnetic compatibility

Frequently asked questions

What type of motor is the BA H 225 series?

The BAH series consists of asynchronous three-phase totally enclosed fan cooled brake motors.

What ambient temperature range is guaranteed for the motor nameplate performance?

The performance and characteristics shown on the motor nameplate are guaranteed between -15 °C and +40 °C.

What insulation resistance check should be made before starting the motor?

Check that the earth insulation resistance is not less than 25 MΩ, measured with a 500 V DC Megger instrument.

Can BA H 225 series motors be used in hazardous environments?

No. The BAH series does not include motors suitable for hazardous environments.