Data sheet for the Mobius FlexReady large-scale parvovirus filtration system with single-use Flexware flow paths and Viresolve Pro devices.
This data sheet describes the Mobius FlexReady system for large-scale virus filtration, which combines single-use Flexware components, Viresolve Pro and Pro+ Magnus/Shield devices, and production-scale hardware. The system is pre-designed and pre-optimized for parvovirus filtration, with a design capacity of up to 5 kg of protein or 2000 L of volume (expressed as 2.5 g/L) and membrane areas from 0.51 m² to 3.06 m².
The document lists design features such as the Viresolve Pro Magnus clamp, low-pulse single-use pump chambers, constant-pressure or constant-flow operation, optional filtrate scales and flow meters, and an intuitive touchscreen interface. A parameter table covers the VF3 5 LPM, VF3 20 LPM and VF3 40 LPM variants, including dimensions, utilities, pumps, valves, pressure switches, sensors, automation (Siemens CPU and Simatic screen) and materials of construction. Because the flow path is single-use, no cleaning validation is required. This manual is written in Chinese.
| Design capacity | 5 kg protein or 2000 L (at 2.5 g/L) |
|---|---|
| Membrane area | 0.51 m² – 3.06 m² |
| Power supply | 110 or 230 V, 50/60 Hz (single phase) |
| Power consumption | 1.4 kW |
| Rated pressure | Up to 4.1 bar (60 psig); 2.1 bar (30 psi) with POD prefilter |
| Process fluid temperature range | 4 to 30 °C |
| Ambient temperature range | 4 to 25 °C, humidity 10–90% (non-condensing) |
| Electrical enclosure | IP 65 |
| Compliance | CE (2014/30/UE, 2006/42/CE) |
| Total weight (approx.) | 390 kg |
| Pump flow range | 0.2–5 LPM (150S), 2–20 LPM (1200S), 4–40 LPM (1200S) |
| Filtrate flux | 420–660 LMH @ 30 psig (0.51 m²) up to 700–1100 LMH @ 50 psig (1.53 m²) |
| Process connection type | TC 3/4" |
| Automation | Semi-automated system with manual valve actuation; Siemens CPU and Simatic screen |
| Filtrate scale | 0–600 kg or 0–3000 kg, 0.1% FS (Mettler-Toledo Deckmate 2888 or PFA579-FM3000) |
It is designed to process up to 5 kg of protein or 2000 L of volume (expressed as 2.5 g/L), with membrane areas from 0.51 m² to 3.06 m².
No. The flow path is single-use, so cleaning validation is not needed, and there is no product contact requiring cleaning validation.
It supports constant-pressure operation using Viresolve Pro solution delta-pressure feedback and pump speed control, or constant-flow operation using pressure feedback and pump speed control.
The system requires 110 or 230 V, 50/60 Hz single-phase power with N and G, and consumes 1.4 kW.