German quick start guide for the Leo Bodnar GPSDO-2-Port and GPSDO-mini GPS-controlled frequency standards, with setup, PC configuration and specifications.
This two-page German quick guide covers the GPSDO-2-Port and GPSDO-mini GPS-controlled frequency standards. It states that the two versions are technically identical but differ in dimensions, connection options, output level and power-supply options. Developer and producer is Leo Bodnar.
Each unit has an internal temperature-compensated oscillator (TCXO) with stability of ≤0.5 ppm and a GPS receiver module with an SMA antenna connector. A digital PLL uses the TCXO and GPS signal as reference; a blinking red LED indicates the PLL is not locked, while steady light indicates locked operation. Output frequency and level are configured with the manufacturer's PC software, and the configuration data remain stored in the unit. This manual is written in German.
| Output frequency | 400 Hz to 810 MHz, adjustable with PC software |
|---|---|
| Frequency stability | ≤1 × 10^-9 with locked control loop |
| TCXO stability | ≤0.5 ppm |
| GPS antenna | 1575.42 MHz, SMA connector, 3 m cable |
| GPSDO-2-Port output level | 7.7 dBm to 13.3 dBm, selectable in four steps |
| GPSDO-2-Port outputs | 2 × BNC, 50 Ω, primary and secondary output |
| GPSDO-2-Port supply voltage | 5 to 14 V via hollow-plug connector or 5 V via USB-B |
| GPSDO-2-Port current consumption | ≤270 mA |
| GPSDO-2-Port dimensions | 110 mm × 60 mm × 27 mm (L × W × H) |
| GPSDO-2-Port mass | 130 g without antenna |
| GPSDO-mini output level | 6.4 dBm to 10.3 dBm, selectable in four steps |
| GPSDO-mini output | SMA socket, 50 Ω |
| GPSDO-mini supply voltage | 5 V via Mini-USB |
| GPSDO-mini current consumption | ≤250 mA |
| GPSDO-mini dimensions | 73 mm × 40 mm × 16 mm (L × W × H) |
| GPSDO-mini mass | 50 g without antenna |
The text says they are technically identical and differ in dimensions, connection options, output level and power-supply options.
After the internal search, click Update to store the found data in the hardware.
It indicates that the PLL is not locked and the signal is therefore not stable; steady light indicates locked operation.
It operates from 5 V supplied through the Mini-USB connection.