LeCroy 3412/3412E 16-Channel 200 MHz CAMAC Discriminator Operator's Manual

Operator's manual for the LeCroy 3412/3412E 16-channel, 200 MHz CAMAC discriminator, covering setup, operation, theory, and specifications.


LeCroy 3412/3412E 16-Channel 200 MHz CAMAC Discriminator Operator's Manual - cover page
Brand
LeCroy
Category
Other Electronics
Document type
User Manual
Language
English
Pages
29
File format
PDF
File size
431 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
11616E17ACD4010765054859ECE40D2F

About this manual

This manual covers the LeCroy Model 3412/3412E 16-channel, 200 MHz CAMAC discriminator. It provides setup and operation instructions, plus theory of operation and other functional information.

It includes installation notes on cooling and crate power, threshold and output width adjustment, veto and mask inputs, test mode, and CAMAC commands and function codes.

What's inside

  • General Information
  • Product Description
  • Specifications
  • Control and Connectors
  • Installation
  • Operating Instructions
  • Theory of Operation
  • CAMAC Commands And Function Codes
  • Threshold
  • Veto Input

Specifications

Cooling exhaust air temperatureLess than 50 °C
Power requirementSignificant power from the -6 V line
Threshold voltage range0 to -10 V
Remote threshold DAC outputVo = 5(X/4095) V
Width voltage rangeAbout 1.4 to 11.4 V
Output pulse width rangeLess than 5 ns to over 100 ns
Fast veto timingLeading edge must precede input by at least 6 ns
Rear panel mask levelsECL logic 1 true, ECL 0 complementary

Frequently asked questions

What is the warranty period for the LeCroy 3412/3412E?

LeCroy warrants its instrument products to operate within specifications under normal use and service for one year from the date of shipment.

What cooling is required for the Model 3412?

Fans must move sufficient air to keep exhaust air temperature below 50 °C.

How is the threshold set in remote mode?

A 12-bit DAC (AD7245) sets it, with output voltage Vo = 5(X/4095) V.

What timing is required for the fast veto input?

Its leading edge must precede the input to be vetoed by at least 6 ns.

Download PDF (431 KB)