About this manual

The QLS device splits a single 4-20 mA, 1-5V, 0-5V or 0-10V input signal into four independent 4-20 mA outputs. Each output can be adjusted for zero and span, and features ±10V common mode isolation. It supports both AC and DC power options and includes diagnostic LEDs and loop current test points. The device solves problems with traditional series current loops by allowing independent operation of each output loop.

The unit is designed for DIN rail mounting and is compact, weighing only 159 g. It can power 2- or 3-wire transmitters and includes specifications for voltage compliance, load regulation, and environmental conditions.

What's inside

  • Features
  • Problems with Current Loop Loads in Series
  • QLS Loop Splitter / Retransmitter Solution
  • Specifications
  • Theory of Operation
  • Safe Operation
  • Ordering Guide

Specifications

Input Signal Types4-20 mA, 1-5V, 0-5V, 0-10V (jumper selectable)
Number of Outputs4
Power Input (QLS-1)85-264 Vac or 90-300 Vdc
Power Input (QLS-2)10-48 Vdc or 12-32 Vac
Common Mode Voltage±10V
Zero & Span Adjustment±10% for each output
Isolation264 Vac
Load Regulation Accuracy±0.005% of span
Dimensions22.5 x 103 x 128 mm
Weight159 g

Frequently asked questions

What input signal types does the QLS accept?

It accepts 4-20 mA, 1-5V, 0-5V, or 0-10V input signals, selectable via jumpers.

How many outputs does the QLS have?

It has four independent 4-20 mA outputs.

What is the common mode voltage between remote and local grounds?

It allows a common mode voltage of ±10V between remote and local grounds.

What power options are available for the QLS?

The QLS-1 model accepts 85-264 Vac or 90-300 Vdc, while the QLS-2 model accepts 10-48 Vdc or 12-32 Vac.