Kinetic Infrared Urinal Flush Control Installation and Setup Guide

Installation, wiring and setup guide for the Kinetic infrared urinal flush control, with battery or mains mounting options and hygiene/economy modes.


Kinetic Infrared Urinal Flush Control Installation and Setup Guide - cover page
Brand
kinetic
Category
Other
Document type
Installation Guide
Language
English
Pages
10
File format
PDF
File size
3.3 MB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
185B6ADF1067B5FE81A5879252946BCE

About this manual

This booklet covers the Kinetic infrared urinal flush control, a controller and valve set that monitors washroom traffic and works with a cistern and auto syphon to adjust urinal flushing time. It lists the pack contents and describes three mounting options: pipe mounted (battery only), flush mounted and remote mounted (battery and mains powered).

The guide explains installation requirements, valve fitting, controller wiring for battery and mains operation, and setup, including the hygiene and economy operating modes and the 12- or 24-hour flush when no movement is detected. It conforms to Water Regulations and is WRAS Approved, and is marked © 2016 Thomas Dudley Ltd.

What's inside

  • Pack contents
  • Introduction and operating modes
  • Installation requirements
  • Installing the valve
  • Kinetic controller pipe mounted (batteries only)
  • Remote mounted (battery & mains powered)
  • Wiring the Kinetic controller
  • Flush mounted (batteries & mains powered)
  • Setting up the Kinetic

Specifications

Recommended water pressure0.1 - 10.0 bar (1.45-145 PSI)
Flow restrictor6 L/min, pre-fitted in valve
Power supplyBattery (4x AA) or mains via 3A fused spur
Maximum urinals per controllerUp to 5 urinals/trough per cistern
Hygiene mode activation time60 minutes, decreasing by 4 minutes to a minimum of 40 minutes
Economy mode activation time80 minutes, decreasing by 4 minutes to a minimum of 60 minutes
No-movement flush intervalEvery 12 hours (hygiene) or 24 hours (economy)
Minimum pipe gap at cistern140mm cut gap, minimum 20mm from pipe to top of cistern
Bezel clamp range0mm - 32mm

Frequently asked questions

What are the operating modes of the Kinetic urinal flush control?

It has two modes: hygiene mode and economy mode. Hygiene mode flushes after 60 minutes of detected movement and economy mode after 80 minutes, each decreasing by 4 minutes with further movement.

Can the Kinetic be mains powered?

Yes, in flush mounted and remote mounted installations. A mains powered unit must be installed by a qualified electrician with a 3A fused spur.

When should the flow restrictor be removed?

Remove the pre-fitted flow restrictor if water pressure is below 1 bar (15 psi).

How many urinals can one Kinetic flush?

Up to 5 urinals or a trough, provided the cistern and auto-syphon conform to the water regulations; one Kinetic is required per cistern.

Download PDF (3.3 MB)