Installation, wiring and setup guide for the Kinetic infrared urinal flush control, with battery or mains mounting options and hygiene/economy modes.
This booklet covers the Kinetic infrared urinal flush control, a controller and valve set that monitors washroom traffic and works with a cistern and auto syphon to adjust urinal flushing time. It lists the pack contents and describes three mounting options: pipe mounted (battery only), flush mounted and remote mounted (battery and mains powered).
The guide explains installation requirements, valve fitting, controller wiring for battery and mains operation, and setup, including the hygiene and economy operating modes and the 12- or 24-hour flush when no movement is detected. It conforms to Water Regulations and is WRAS Approved, and is marked © 2016 Thomas Dudley Ltd.
| Recommended water pressure | 0.1 - 10.0 bar (1.45-145 PSI) |
|---|---|
| Flow restrictor | 6 L/min, pre-fitted in valve |
| Power supply | Battery (4x AA) or mains via 3A fused spur |
| Maximum urinals per controller | Up to 5 urinals/trough per cistern |
| Hygiene mode activation time | 60 minutes, decreasing by 4 minutes to a minimum of 40 minutes |
| Economy mode activation time | 80 minutes, decreasing by 4 minutes to a minimum of 60 minutes |
| No-movement flush interval | Every 12 hours (hygiene) or 24 hours (economy) |
| Minimum pipe gap at cistern | 140mm cut gap, minimum 20mm from pipe to top of cistern |
| Bezel clamp range | 0mm - 32mm |
It has two modes: hygiene mode and economy mode. Hygiene mode flushes after 60 minutes of detected movement and economy mode after 80 minutes, each decreasing by 4 minutes with further movement.
Yes, in flush mounted and remote mounted installations. A mains powered unit must be installed by a qualified electrician with a 3A fused spur.
Remove the pre-fitted flow restrictor if water pressure is below 1 bar (15 psi).
Up to 5 urinals or a trough, provided the cistern and auto-syphon conform to the water regulations; one Kinetic is required per cistern.