Kepco KLP Series Programmable DC Power Supply Product Leaflet

Kepco KLP series 1200 W programmable DC power supplies with hyperbolic power limit, GPIB, RS-232 or Ethernet, and analog I/O.


Kepco KLP Series Programmable DC Power Supply Product Leaflet - cover page
Brand
KEPCO
Category
Power Management
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
282 KB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
191F62EEC7758F784CE25D16F047BECA

About this manual

Kepco's Series KLP comprises seven programmable DC power supply models rated from 0-10 V to 0-600 V, all within a 1200 watt power limit. The supplies use high-frequency switch-mode topology in a 1U, 19-inch rack-mountable package and feature a hyperbolic power limit that expands the operating region beyond a conventional rectangular CV/CC locus.

Digital programming options differ by suffix: -1200 models provide GPIB and RS-232, while -1.2K models provide GPIB and an LXI Ethernet (LAN) port. All models include isolated analog programming inputs and outputs, and the leaflet lists output, input, model-table, and feature specifications.

What's inside

  • RS-232
  • IEEE-488
  • ETHERNET
  • ANALOG I/O
  • KLP MODEL TABLE
  • KLP OUTPUT CHARACTERISTICS
  • KLP INPUT CHARACTERISTICS
  • FEATURES

Specifications

Power limit1200 W
AC input voltage100-240 V AC nominal; 100-255 V AC wide range
Inrush current40 A peak at 265 V AC; 20 A at 132 V AC
Leakage current5 mA at 115 V AC, 60 Hz; 10 mA at 230 V AC, 50 Hz
Power factor0.99
DC input voltage125-420 V DC
Input frequency50-60 Hz nominal; 45-440 Hz range
Output hold-up10 ms typical
Stabilizer typeCV/CC
Voltage/current adjustment range0-100% of rated voltage; no minimum load
Source effect0.01% E max voltage; 0.01% I max current
Load effect0.01% E max voltage; 0.02% I max current
Time effect (drift)0.05%/24 hr
Error sensing0.25 V per wire above rated output
Isolation voltage600 V DC or peak
Transient recovery1% of E max excursion; 2 ms recovery
Overvoltage protection20-120% of E max
Overcurrent protection72-120% of I max
Overtemperature protectionShutdown; user selectable recovery
Output lead fault protectionShutdown
Parallel operationActive load sharing within 5% of I rated; up to 5 units
Programming resolution0.024%
Readback accuracy0.1% of E max or I lim
RS-232 baud rateup to 38,400
GPIB addresses1 to 31 (factory default 6)
Analog input default0 to 10 V DC or 0 to 10 kohm
Analog readback0 to 10 V proportional
Dimensions1.75 in x 19 in x 17.5 in (44.45 x 482.6 x 443.7 mm)
Weight15 lb (6.82 kg)
ModelsSeven models: KLP 10-150-*, KLP 20-120-*, KLP 36-60-*, KLP 75-33-*, KLP 150-16-*, KLP 300-8-*, KLP 600-4-*
Suffix interfaces-1200 includes RS-232; -1.2K includes LAN (LXI)

Frequently asked questions

What digital interfaces do KLP models provide?

-1200 models provide GPIB and RS-232; -1.2K models provide GPIB and an Ethernet (LAN/LXI) port.

What is the KLP power limit?

The KLP has a 1200 watt power limit.

What is the programming resolution and readback accuracy?

Programming resolution is 0.024% and readback accuracy is 0.1% of E max or I lim.

What are the default analog input levels?

The default analog inputs are 0 to 10 V DC voltage or 0 to 10 kohm resistance.

Download PDF (282 KB)