Kepco KLP series 1200 W programmable DC power supplies with hyperbolic power limit, GPIB, RS-232 or Ethernet, and analog I/O.
Kepco's Series KLP comprises seven programmable DC power supply models rated from 0-10 V to 0-600 V, all within a 1200 watt power limit. The supplies use high-frequency switch-mode topology in a 1U, 19-inch rack-mountable package and feature a hyperbolic power limit that expands the operating region beyond a conventional rectangular CV/CC locus.
Digital programming options differ by suffix: -1200 models provide GPIB and RS-232, while -1.2K models provide GPIB and an LXI Ethernet (LAN) port. All models include isolated analog programming inputs and outputs, and the leaflet lists output, input, model-table, and feature specifications.
| Power limit | 1200 W |
|---|---|
| AC input voltage | 100-240 V AC nominal; 100-255 V AC wide range |
| Inrush current | 40 A peak at 265 V AC; 20 A at 132 V AC |
| Leakage current | 5 mA at 115 V AC, 60 Hz; 10 mA at 230 V AC, 50 Hz |
| Power factor | 0.99 |
| DC input voltage | 125-420 V DC |
| Input frequency | 50-60 Hz nominal; 45-440 Hz range |
| Output hold-up | 10 ms typical |
| Stabilizer type | CV/CC |
| Voltage/current adjustment range | 0-100% of rated voltage; no minimum load |
| Source effect | 0.01% E max voltage; 0.01% I max current |
| Load effect | 0.01% E max voltage; 0.02% I max current |
| Time effect (drift) | 0.05%/24 hr |
| Error sensing | 0.25 V per wire above rated output |
| Isolation voltage | 600 V DC or peak |
| Transient recovery | 1% of E max excursion; 2 ms recovery |
| Overvoltage protection | 20-120% of E max |
| Overcurrent protection | 72-120% of I max |
| Overtemperature protection | Shutdown; user selectable recovery |
| Output lead fault protection | Shutdown |
| Parallel operation | Active load sharing within 5% of I rated; up to 5 units |
| Programming resolution | 0.024% |
| Readback accuracy | 0.1% of E max or I lim |
| RS-232 baud rate | up to 38,400 |
| GPIB addresses | 1 to 31 (factory default 6) |
| Analog input default | 0 to 10 V DC or 0 to 10 kohm |
| Analog readback | 0 to 10 V proportional |
| Dimensions | 1.75 in x 19 in x 17.5 in (44.45 x 482.6 x 443.7 mm) |
| Weight | 15 lb (6.82 kg) |
| Models | Seven models: KLP 10-150-*, KLP 20-120-*, KLP 36-60-*, KLP 75-33-*, KLP 150-16-*, KLP 300-8-*, KLP 600-4-* |
| Suffix interfaces | -1200 includes RS-232; -1.2K includes LAN (LXI) |
-1200 models provide GPIB and RS-232; -1.2K models provide GPIB and an Ethernet (LAN/LXI) port.
The KLP has a 1200 watt power limit.
Programming resolution is 0.024% and readback accuracy is 0.1% of E max or I lim.
The default analog inputs are 0 to 10 V DC voltage or 0 to 10 kohm resistance.