Kepco RAX 300W Series Switching Power Supply Operation Manual

This file is the RAX 300W Series Switching Power Supply Operation Manual, which introduces the features and characteristics of the products in the series, including power input and output, power working principle, and power safety protection measures.


Kepco RAX 300W Series Switching Power Supply Operation Manual - cover page
Brand
KEPCO
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
165 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
66A7774B25F2824D22BE884F0BDAC27A

About this manual

This manual covers installation and operation of the Kepco RAX 300W Series switching power supplies. It includes specifications, input/output ratings, voltage adjustment, remote control, and safety features. The units operate on 115V or 230V AC or 240V–370V DC input and feature overvoltage protection, current limiting, and soft-start circuits. Units are enclosed in aluminum cases with LED output indicators.

What's inside

  • Introduction
  • Specifications
  • Operation
  • Installation
  • Voltage Adjustment
  • Remote Control
  • Safety and Protection

Specifications

Input Voltage120V AC (85–132V), 220–240V AC (170–264V), 240–370V DC
Switching Frequency145 kHz
Output Voltage Range5V to 48V
Efficiency77% typical
Operating Temperature0°C to 71°C
Isolation Voltage3.75 kV AC between input and output
Current Limit65.0–70.0A for RAX 5-60K
Output Holding Time20 milliseconds minimum

Frequently asked questions

What input voltage options are available for the RAX 300W Series?

The units can operate on 115V AC (85–132V), 220–240V AC (170–264V), or 240–370V DC.

How is the output voltage adjusted?

Adjust voltage by monitoring the + and - sense terminals with a precision voltmeter and turning the voltage control to the desired value.

What is the output holding time if input is interrupted?

The output is maintained for 20 milliseconds minimum upon input interruption.

What is the efficiency of the RAX 300W Series?

The efficiency is 77% typical.

Download PDF (165 KB)