About this manual

This document serves as the operating manual for the Kemppi FastMig KM series of three-phase MIG welding power supplies. It provides comprehensive instructions on installing the unit, including positioning requirements and electrical connections for the mains and welding cables.

The guide details how to operate the control panel, adjust parameters such as wire feed speed and arc dynamics, and interpret indicator lamps. It also includes a troubleshooting section for common errors like overload or phase loss, along with maintenance procedures and technical specifications.

What's inside

  • Introduction
  • Installation
  • Using the Equipment
  • Troubleshooting
  • Maintenance

Frequently asked questions

What is the minimum required free space in front of and behind the machine for air circulation?

There must be at least 20 cm of free space in front and behind the machine to ensure cooling air circulation.

How long can the cooling fan run after welding stops depending on the machine temperature?

The cooling fan may continue to run for up to 10 minutes after welding is finished, depending on the machine temperature.

What is the recommended cross-section for the welding cable used with the FastMig KM 300?

The recommended cross-section for the welding cable with the FastMig KM 300 is 50 – 70 mm².