Chinese user manual for the Interroll GatewayControl interface, covering safety, installation, parameterization, operation and troubleshooting.
Interroll GatewayControl is part of the ConveyorControl system and is used in industrial applications to control RollerDrives EC310. It connects the system to Profibus, Profinet or EtherNet/IP, runs as an I/O adapter, manages up to 200 zones, and supports I/O-PLC control and full PLC control.
This Chinese user manual, version 1.0 (04/2014), is a translation of the original instructions and a supplement to the ConveyorControl system operating instructions. It covers safety, product information, technical data, planning and parameterization, assembly and electrical installation, commissioning and operation, maintenance, troubleshooting, shutdown and disposal, plus appendices for PLC data, faults, program examples and bus assignments. This manual is written in Chinese.
| Fieldbus interfaces | Profibus, Profinet, EtherNet/IP |
|---|---|
| Zone management | Up to 200 zones |
| Data exchange | Explicit (cyclic) and implicit (acyclic) data exchange |
| Control modes | I/O-PLC control; full PLC control |
| Bus termination | Integrated terminating resistor for the bus cable |
It is used in industrial applications and industrial environments to control RollerDrives EC310 as part of a conveyor system.
It can connect the system to Profibus, Profinet or EtherNet/IP.
It can manage up to 200 zones in the ConveyorControl system.
No; the manual prohibits use in environments with explosion hazards.