The Interroll DriveControl DriveControl 20 DriveControl 54 DriveControl 2048 operating manual introduces the use method, precautions, safety information and other contents of the product
This operating manual covers the Interroll DriveControl models 20, 54, and 2048. It serves as a component of the product, containing important advice and information regarding different operating phases, from assembly and electrical installation to start-up, configuration, and maintenance. The document emphasizes that the equipment is intended for industrial use only and must be operated by qualified personnel.
| Rated voltage | 24 V DC, protected extra-low voltage (PELV) |
|---|---|
| Voltage range | 19 to 26 V DC |
| Current consumption (With RollerDrive) | Up to 5 A |
| Current consumption (Without RollerDrive) | 0.1 A |
| Protection rate | IP20 / IP54 |
| Weight | 500 g (incl. base plate) |
| Ambient temperature in operation | 0 °C to +40 °C |
| Ambient temperature during transport and storage | -40 °C to +85 °C |
| Altitude of installation site | Max. 1000 m |
The DriveControl may only be used in an industrial environment for industrial purposes within the stipulated performance limits.
All work on electrical equipment must generally only be performed by a qualified electrician.
No, it must not be used in a residential environment without further examination and without the use of adapted EMC protective measures.