International Interzinc 2277 is a two-component inorganic zinc silicate primer meeting SSPC Paint 20 Level 2 for corrosion protection of bridges, tanks, and…
Interzinc 2277 is a two-component, solvent-based inorganic zinc silicate primer that complies with SSPC Paint 20 Level 2 and ASTM D520 Type II zinc dust standards. It provides excellent corrosion protection for properly prepared steel substrates in new construction and maintenance projects such as bridges, storage tanks, pipelines, and structural steel. When overcoated with appropriate topcoats, the system can withstand continuous dry heat up to 540°C.
The product is applied by airless spray, air spray, brush, or roller after mixing Part A (base) and Part B (zinc dust) at a 4:1 volume ratio. Surface preparation requires abrasive blasting to Sa2½ (ISO 8501-1) or SSPC-SP6 with a 40–75 µm profile. Drying times vary with temperature: at 25°C touch dry in 10 minutes, hard dry in 1 hour, and minimum overcoating interval of 4.5 hours. Compatible topcoats include Intercure 200, Intergard 475HS, Intertherm 50, and others. The primer has a volume solids of 66%, recommended dry film thickness of 50–75 µm, and a theoretical coverage of 8.80 m²/L at 75 µm DFT. This manual is written in Chinese.
| Typical Dry Film Thickness | 50-75 µm (2-3 mils) |
|---|---|
| Theoretical Coverage | 8.80 m²/L at 75 µm DFT |
| Airless Spray Tip Size | 0.38-0.53 mm (15-21 thou) |
| Airless Spray Pressure | ≥112 kg/cm² (1593 psi) |
| Surface Preparation Standard | Sa2½ (ISO 8501-1) or SSPC-SP6 |
| Surface Roughness | 40-75 µm (1.5-3.0 mils) |
| Maximum Dry Film Thickness | 125 µm (5 mils) |
| High Temperature Resistance (with Intertherm 50) | 540°C |
| Shelf Life at 25°C | 12 months minimum |
The maximum dry film thickness is 125 µm (5 mils); for high-temperature service limit to 50 µm.
Compatible topcoats include Intercure 200, Intergard 475HS, Intercure 420, Interseal 670HS, Intergard 251, Intergard 269, Intertherm 50, and Interplus 356.