ifm electronic IFT203 IFB3004BBPKG/M/V4A/US-104-DPS Inductive Sensor Datasheet

ifm electronic IFT203 inductive sensor data sheet for IFB3004BBPKG/M/V4A/US-104-DPS, with electrical data, sensing range, approvals and connection details.


ifm electronic IFT203 IFB3004BBPKG/M/V4A/US-104-DPS Inductive Sensor Datasheet - cover page
Brand
IFM Electronic
Category
sensor
Document type
Datasheet
Language
English
Pages
3
File format
PDF
File size
179 KB
Published
22 November, 2026
Updated
22 November, 2026
MD5 checksum
E12B2F1CF8EDE2F9919EBBA0955B1A41

About this manual

This data sheet describes the ifm electronic IFT203 inductive sensor identified as IFB3004BBPKG/M/V4A/US-104-DPS. It lists electrical data, detection zone, accuracy/deviations, operating conditions, tests/approvals, mechanical data, accessories and connection information.

The listed electrical data include 10...36 DC operating voltage, PNP output, normally open output function and 800 Hz switching frequency. The sensing range is 4 mm, with an operating distance of 0...3.25 mm and protection IP 68; IP 69K; ("COP").

What's inside

  • Electrical data
  • Outputs
  • Detection zone
  • Accuracy / deviations
  • Operating conditions
  • Tests / approvals
  • Mechanical data
  • Accessories
  • Electrical connection
  • Connection

Specifications

Operating voltage10...36 V DC
Current consumption10 mA at 24 V
Protection classII
Output designPNP
Output functionnormally open
Max. voltage drop switching output DC2.5 V
Permanent current rating of switching output DC100 mA
Switching frequency DC800 Hz
Sensing range4 mm
Operating distance0...3.25 mm
Hysteresis1...20 % of Sr
Ambient temperature0...100 °C
ProtectionIP 68; IP 69K; ("COP")
MTTF1676 years
Weight24.8 g
DimensionsM12 x 1 / L = 45 mm
Mountingflush mountable
Connector1 x M12; contacts gold-plated

Frequently asked questions

What is the operating voltage of the ifm electronic IFT203?

The operating voltage is 10...36 DC.

What is the sensing range of IFB3004BBPKG/M/V4A/US-104-DPS?

The sensing range is 4 mm; the operating distance is 0...3.25 mm.

What output does the IFT203 inductive sensor have?

It has a PNP electrical design with a normally open output function.

What protection ratings are listed for the IFT203?

The listed protection ratings are IP 68 and IP 69K ("COP").

Download PDF (179 KB)

More IFM Electronic Manuals