Hitech EM125N Dual Preset Electronic Counter User Manual

This manual covers the installation, wiring, function programming, parameter settings, and technical specifications for the Hitech EM125N dual preset…


Hitech EM125N Dual Preset Electronic Counter User Manual - cover page
Brand
Hi-Tech
Document type
User Manual
Language
Chinese
Pages
13
File format
PDF
File size
1 MB
Published
14 October, 2026
Updated
14 October, 2026
MD5 checksum
A910EA5B6076D5E682E7D153830E509E

About this manual

The Hitech EM125N is a 5-digit LED display electronic counter featuring dual preset functions, ratio counting capabilities, and six selectable counting modes. It supports two relay output channels with adjustable timing or steady-state outputs and offers high power adaptability without requiring a battery for data retention.

This guide details the installation dimensions and pin definitions for wiring connections. It explains how to program function codes (such as counting direction, encoder modes, and reset logic) and parameter settings (including preset values and correction factors). The document also describes dynamic versus static reset behaviors and output modes like arrival and region outputs. This manual is written in Chinese.

What's inside

  • Installation Dimensions
  • Wiring Pin Definitions
  • Function Programming
  • Parameter Settings
  • Correction Values
  • Counting Modes
  • Reset Functions
  • Output Modes
  • Technical Specifications

Specifications

Display Type5-digit LED display
Character Height9.2mm
Counting Frequency (Contact)30Hz
Counting Frequency (Unfiltered)5kHz
Relay Output Capacity250V 3A
Power Input Voltage12-24V DC
Data Retention Time10 years

Frequently asked questions

What are the two counting frequency options?

The counter supports a filtered contact signal input at 30Hz or an unfiltered input up to 5kHz.

How many relay output channels does the EM125N have?

The device features two relay output channels, each capable of adjustable timing or steady-state operation.

What is the maximum input current for the power supply?

The maximum input current, including sensor output, is 500mA.

Can the counter operate without a battery?

Yes, the device does not require a battery and can retain data for ten years.

Download PDF (1 MB)