User manual for the HC-S rotary blower covering structure, operation, installation, maintenance, troubleshooting, and warranty.
The HC-S rotary blower is intended for applications requiring air at 0.1 to 0.5 kgf/cm2. It consists of a motor, air filter, blower host, air chamber, base/oil tank, drip oiler, safety valve, pressure gauge, check valve, and oil filter.
The manual explains the blower's working principle, installation and trial-operation precautions, maintenance points, repair methods, troubleshooting tables, fault tree, and one-year warranty terms. This manual is written in Chinese.
| Air pressure range | 0.1 to 0.5 kgf/cm2 |
|---|---|
| Lubricant grade | ISO standard N68 lubricating oil |
| Oil drip rate | 12-15 drops per minute |
| Safety valve opening pressure | 1.5 times working pressure |
| Warranty period | One year from delivery |
Use ISO standard N68 lubricating oil; a lower grade may be used in cold regions.
The oiler should drip 12 to 15 drops per minute.
The product has a one-year warranty from the delivery date.