This document describes the features and characteristics of the HC 3315, 3330, 3340 Chlorine/Bromine High Capacity Commercial Feeder, including extra large capacity models, compatibility with tricolor or bromine tablets or sticks, no special venting required, completely enclosed design with no escaping gases, positive external no-clog control valve, and direct feeding of sanitizer to the pool.
This manual provides installation and operating instructions for Pentair HC 3315, 3330, and 3340 high capacity commercial chlorine and bromine feeders. These extra-large capacity models are designed for hard plumbing installation using 1" PVC pipe and operate by pressure differential to circulate sanitizer directly to the pool. The document includes specific warnings regarding copper plumbing and the necessity of a fireman's switch when used with heaters.
| Capacity (HC 3315) | 15 LBS |
|---|---|
| Capacity (HC 3330) | 30 LBS |
| Capacity (HC 3340) | 40 LBS |
| Max pool size (Trichlor, HC 3315) | 97,600 gals |
| Max pool size (Bromine, HC 3340) | 61,500 gals |
No, you should never install the feeder into copper plumbing as pipe damage could occur.
The recommended start up setting is #1.
No, these models do not require special venting.