Halsey Taylor Owners Manual for the Model 4715 floor mounted steel fountain: installation, water connections, stream adjustment, troubleshooting and parts list.
This is the Halsey Taylor Owners Manual (document 97167C, Rev. M - 6/11) for the Model 4715 Floor Mounted Steel Fountain. It gives installation steps, water supply and drain connection details, actuation of the quick connect water fittings, stream height adjustment, troubleshooting and maintenance notes, and an itemized parts list. The manual states that all service is to be performed by an authorized service person and that the installation must comply with plumbing, electrical, and other applicable codes.
Installation requires a smooth, flat, finished mounting surface with a support structure capable of carrying a 300 lb. load and 3/8" minimum screws or bolts (not furnished). Water is supplied through a shut-off valve (not furnished) and 3/8" O.D. unplated copper tube, with 1-1/4" IPS waste; the fountain is rated for 20-105 PSI inlet water pressure. A separate installer note warns that grounding of electrical equipment to water lines can cause electrical feedback and electrolysis, and advises plastic drain fittings to electrically isolate the fountain from the building plumbing.
| Inlet water pressure | 20-105 PSI |
|---|---|
| Water supply tubing | 3/8" O.D. unplated copper tube |
| Waste connection | 1-1/4" IPS |
| Mounting structure load rating | 300 lb. |
| Mounting hardware size | 3/8" minimum screws or bolts |
| Factory stream height setting | 35 PSI supply pressure |
| Recommended stream landing | approx. 6-1/2" from bubbler |
It is rated for an inlet water pressure of 20-105 PSI; a pressure reducing regulator should be used if the supply exceeds 105 PSI.
Turn the screw on item 20 with a small screwdriver through the small hole in the push button; clockwise raises the stream and counter-clockwise lowers it.
Mineral deposits on the orifice can cause this; they may be removed with a small round file not over 1/8" diameter or a small diameter wire, without filing or cutting the orifice material.
A 3/8" unplated copper water line is installed between the shut-off valve and the cooler, with the tube pushed straight into the fitting to a positive stop of about 3/4".