This manual is designed to help you easily and correctly install the 4410 model fountain
This guide provides step-by-step instructions for installing the Halsey Taylor 4410 floor-mounted tubular fountain. It covers mounting requirements, plumbing connections, electrical grounding, and maintenance. The document includes diagrams, part lists, and troubleshooting tips to ensure correct installation and compliance with local codes.
The fountain is designed for easy installation on smooth, flat surfaces and requires 3/8" copper tubing for water supply and 1-1/4" IPS for drain. It is rated for 20-105 PSI water pressure and includes quick-connect fittings for tubing. Electrical grounding precautions are included to prevent electrolysis and metallic taste in water.
| Water Pressure Rating | 20-105 PSI |
|---|---|
| Water Supply Tube | 3/8" O.D. unplated copper tube |
| Drain Size | 1-1/4" IPS |
| Mounting Load Capacity | 300 lb minimum |
The fountain is rated for inlet water pressure of 20-105 PSI.
Water supply must be 3/8" O.D. unplated copper tube, and drain must be 1-1/4" IPS.
Use a small straight bladed screwdriver to turn the adjustment screw through the access hole in the push button. Clockwise raises the stream, counterclockwise lowers it.