Owner's manual for the Haier 49-5000094-6 high wall duct-free heat pump system: safety information, remote control settings, cleaning and troubleshooting.
This is the owner's manual for the Haier 49-5000094-6 High Wall Duct-Free System, an R410A heat pump. It opens with important safety information about installation, cleaning the air filter, refrigerant handling and remote control batteries, then explains the remote control features and settings, emergency operation, optimizing performance, cleaning the front cover and filter, troubleshooting tips, and a limited warranty note that refers readers to the installation manual for warranty details.
The remote control section describes the power, COOL, HEAT, DRY and FAN mode buttons, temperature adjustment within 60°F-86°F (16°C-30°C), fan speed, TURBO, QUIET, louver up/down and side/side control, SLEEP, Fahrenheit/Celsius toggle, the EXTRA FUNCTION menu (A-B selection, auto mode, louver lock, timer ON/OFF, 50°F heating), CONFIRM/CANCEL, LOCK, LIGHT and RESET. It also covers inserting the batteries, the remote's operating distance, and troubleshooting notes such as the 3-minute restart delay and DRY mode fan behavior.
| Operating temperature range | 60°F-86°F (16°C-30°C) |
|---|---|
| Refrigerant | R410A |
| Remote control operating distance | Less than 23 feet, with no obstructions |
| Restart delay after stop | 3 minutes |
| SLEEP function auto shut-off | After 8 hours of run time |
| 50°F heating setpoint | Maintains 50°F |
The operating temperature range is 60°F-86°F (16°C-30°C). The TEMP+ and TEMP- buttons raise or lower the setting.
Remove the filter by pushing up on its center tab, then vacuum off dust or wash it with water and dry it completely. Reattach it with the "FRONT" label facing outward.
It will not restart for 3 minutes to protect the system; the same protection circuit is active for 3 minutes after power is disconnected and reconnected.
Use emergency operation, during which the unit runs automatically and the temperature, fan speed, timer and dry modes cannot be changed.