Guangzhou Light Bridge GQ8002E1 Circuit Automatic Protection Switching Equipment User Manual

This manual details the installation, operation, and maintenance of the GQ8002E1 circuit automatic protection switching equipment.


Guangzhou Light Bridge GQ8002E1 Circuit Automatic Protection Switching Equipment User Manual - cover page
Brand
Guangzhou光桥通信设备
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
395 KB
Published
22 September, 2011
Updated
16 October, 2026
MD5 checksum
BED15794A7D707F9618722985D27D387

About this manual

The Guangzhou Light Bridge Communication Equipment Co., Ltd. GQ8002E1 is a device designed to ensure reliable transmission in digital systems by automatically selecting high-quality signals from two parallel transmission lines. It utilizes a concurrent selection and reception system to switch between channels within microseconds when faults such as loss of signal, frame synchronization errors, or excessive bit errors are detected on the primary path. This manual is written in Chinese.

What's inside

  • Equipment Overview
  • Installation and Commissioning
  • Operation Instructions
  • Troubleshooting

Specifications

Interface TypeE1 Interface
Line CodeHDB3
Frame Loss Switching Time750 us
No Signal Switching Time250 us
AIS Switching Time500 us
Power Supply (DC)24V ~ 48V, no polarity required
Power Supply (AC)220V, 50Hz

Frequently asked questions

What conditions trigger an automatic switch to the backup channel?

The system switches automatically if the primary transmission path experiences no signal (LOS), frame synchronization loss, AIS, or bit errors exceeding 10^-6.

How long does it take to switch channels upon frame synchronization loss?

The switching time from the occurrence of frame synchronization failure to completing the system switch is 750 microseconds.

What happens if both power supplies fail?

When both power supplies fail, the transmission and reception signals automatically default to the Transmission A line.