This manual provides installation, operation, maintenance, and safety instructions for GNU commercial condensing gas storage water heaters.
This document is the user and maintenance manual for the GNU GHE100-R and GNU100-R series of commercial condensing gas storage water heaters. It covers essential safety precautions regarding fire and explosion risks, proper ventilation requirements, and temperature settings to prevent scalding.
The guide details technical specifications for both indoor (RSTG) and outdoor (RSTW) models with varying capacities from 250L to 380L. It includes step-by-step installation procedures, operational instructions for the user interface, maintenance schedules, cleaning advice, and wiring diagrams. This manual is written in Chinese.
| Power Supply | 220V~50Hz |
|---|---|
| Rated Thermal Load | 73kW, 85kW, 99kW |
| Gas Type | Natural Gas 12T (LHV 36MJ/m³) |
| Max Working Water Pressure | 1.05 MPa |
The factory default temperature setting for the water heater is 65°C.
No, natural gas water heaters cannot be used with liquefied petroleum gas. They must not be connected to a fuel type other than what is certified on the nameplate.
The minimum inlet pressure is 1000Pa and the maximum inlet pressure is 3000Pa at the gas valve.