Furuno NavNet TZtouch and TZtouch 2 FLIR M-Series Camera Setup Procedure

Setup instructions for integrating FLIR M-Series IP cameras (M232, M132) with Furuno NavNet TZtouch and TZtouch 2 MFDs.


Furuno NavNet TZtouch and TZtouch 2 FLIR M-Series Camera Setup Procedure - cover page
Brand
Furuno
Category
Other Electronics
Document type
User Manual
Language
Japanese
Pages
11
File format
PDF
File size
1.8 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2A415B4D79C4B9648C51BD96A2D917B5

About this manual

This document provides detailed procedures for integrating FLIR M-Series IP cameras, such as the M232 and M132, into Furuno NavNet TZtouch and TZtouch 2 Multi-Function Displays (MFDs). It covers network configuration, static IP address assignment, and the use of the JCU-3 Joystick Control Unit for camera operation.

The guide explains how to configure the camera and JCU-3 using a PC, assign specific IP addresses to match the Furuno network domain, and perform the final detection and setup on the MFD units. This manual is written in Japanese.

What's inside

  • FLIR Mシリーズとの統合
  • ネットワーク概要
  • FLIR Mシリーズ(IPカメラタイプ)の設定
  • 静的IPアドレスの割り当て
  • NavNet TZtouch とTZtouch2を設定する

Specifications

Recommended Camera IP Address172.31.200.3
Recommended JCU-3 IP Address172.31.200.100
Subnet Mask255.255.0.0

Frequently asked questions

What are the default login credentials for the M-Series camera?

The default username is 'expert' and the default password is 'expert'.

Which FLIR M-Series models are compatible?

The M232 (pan/tilt/zoom) and M132 (tilt/zoom, no panning) IP camera models are mentioned.

Is a separate controller needed for camera operation?

Yes, the JCU-3 (Joystick Control Unit) is required to operate the camera or turn power on/off due to unsupported functions on the MFD.