Franklin Water Treatment HEX-IMX-INTX Series water softener installation instructions and owner's manual covering setup, control valve programming, and…
This manual from Franklin Water Treatment, LLC covers the HEX, IMX & INTX Series Water Softener System. It provides installation instructions, control valve programming, operating displays, and troubleshooting for residential or commercial water softening.
Topics include pre-installation requirements, bypass valve operation, step-by-step installation, specifications, component parts breakdowns, and the ten-year limited warranty.
| Water pressure | 25-100 psi (1.7 – 6.9 bar) |
|---|---|
| Water temperature | 33-100°F (0.5 -37.7°C) |
| Electrical | 115/120 V, 60 Hz |
| Clear water iron removal | 2 ppm or less |
| Regeneration time | 2:00 A.M. |
It removes hardness minerals such as calcium and magnesium through ion exchange.
Regeneration is factory preset to 2:00 A.M.
The system requires water pressure of 25-100 psi.
The bypass valve operates in four positions, including Normal Operation, Bypass, Diagnostic, and Shut Off.