FineTek EPD30 Electromagnetic Flow Meter Operation Manual

This manual covers the operation, installation, wiring, and maintenance of the FineTek EPD30 Electromagnetic Flow Meter for industrial fluid monitoring.


FineTek EPD30 Electromagnetic Flow Meter Operation Manual - cover page
Brand
FineTek
Category
flow transmitter
Document type
User Manual
Language
English
Pages
78
File format
PDF
File size
3.5 MB
Published
17 October, 2026
Updated
17 October, 2026
MD5 checksum
B6D016BFFA68703AFD10C9EAEC767138

About this manual

The FineTek EPD30 Electromagnetic Flow Meter utilizes coil excitation technology to ensure stable performance in complex industrial environments. It is designed to measure the flow of conductive fluids containing solid granules without causing pressure loss or jamming, making it suitable for industries such as power generation, water treatment, and food processing.

The document provides comprehensive instructions on product inspection, safety measures, and correct installation procedures, including grounding requirements. It details the wiring configuration, parameter setting functions via the menu system, and troubleshooting steps for fault inspection and repair.

What's inside

  • Reading Labels
  • Product Warranty
  • Product Inspection
  • Product Features
  • Working Principles
  • Technical Performance
  • Installation
  • Wiring and Using
  • Parameter Functions
  • Fault Inspection and Repair

Specifications

Accuracy±0.5% of reading@1m/s
Medium temperature-20~120℃
Ambient temperature-40~70℃
Fluidic conductivity>5uS/cm
Measuring scope0.1m/s~10m/s
Communication interfaceRS-485 (Modbus)
Protection ratingIP67/NEMA 4X
Operating pressure16 kg/cm2

Frequently asked questions

What is the required straight tube section for installation?

The upstream front requires 5D and the downstream requires 2D of the flow meter.

What is the maximum fluidic temperature permitted?

The maximum fluidic temperature permitted can reach 120℃ when using Teflon lining.

Does the flow meter have a self-diagnosis function?

Yes, it can automatically detect the excited signal, whether the measuring tube is empty, and whether the electrode is stained or damaged.