This manual covers the operation, installation, wiring, and maintenance of the FineTek EPD30 Electromagnetic Flow Meter for industrial fluid monitoring.
The FineTek EPD30 Electromagnetic Flow Meter utilizes coil excitation technology to ensure stable performance in complex industrial environments. It is designed to measure the flow of conductive fluids containing solid granules without causing pressure loss or jamming, making it suitable for industries such as power generation, water treatment, and food processing.
The document provides comprehensive instructions on product inspection, safety measures, and correct installation procedures, including grounding requirements. It details the wiring configuration, parameter setting functions via the menu system, and troubleshooting steps for fault inspection and repair.
| Accuracy | ±0.5% of reading@1m/s |
|---|---|
| Medium temperature | -20~120℃ |
| Ambient temperature | -40~70℃ |
| Fluidic conductivity | >5uS/cm |
| Measuring scope | 0.1m/s~10m/s |
| Communication interface | RS-485 (Modbus) |
| Protection rating | IP67/NEMA 4X |
| Operating pressure | 16 kg/cm2 |
The upstream front requires 5D and the downstream requires 2D of the flow meter.
The maximum fluidic temperature permitted can reach 120℃ when using Teflon lining.
Yes, it can automatically detect the excited signal, whether the measuring tube is empty, and whether the electrode is stained or damaged.