About this manual

This is the operator manual for the Fairbanks Scales 2800 Series Intrinsically Safe Instrument, which uses Intalogix™ technology and is factory mutual approved for hazardous environments. It features a stainless steel NEMA 4X enclosure, a 1.25" LCD weight display, and programmable functions for weighing, tare, and data output. The instrument can be powered by battery or safe-area power supply and supports RS232, RS485, and 4-20mA outputs. It is designed for commercial and non-commercial applications with configurable accuracy up to 30,000 divisions.

What's inside

  • General Information
  • Operation
  • Programming
  • Security
  • Troubleshooting/ Error Codes
  • FM Control Drawings
  • Material Safety Data Sheets
  • Port A/B Data Streams
  • Accessory 2860 Communication Wiring
  • ASCII Codes

Specifications

Model2800 Series Instrument
ApprovalsNTEP: CoC 01-009, FM Approvals: Class I, II, and III; Division 1; Groups A, B, C, D, E, F, and G
Enclosure RatingNEMA 4X, IP65
CapacitiesService programmable up to 999,950 lb, kg, oz, g, tons, lb-oz, or gallons
ResolutionCommercial - Up to 10,000 divisions maximum; Noncommercial - Up to 30,000 divisions maximum
Sensitivity1µv/d (microvolt/division)
Display1.25" height 7 segment LCD weight display, .38" x 3.73" alphanumeric status display
Operating Temperature-10°C to +40°C (+14°F to +104°F)
Chemical ResistanceResistant to all petroleum derivatives and salts

Frequently asked questions

What is the maximum division size for non-commercial applications?

Up to 30,000 divisions maximum.

What types of data outputs are supported?

RS232, RS485, and 4-20mA data outputs.

What is the power supply option for the instrument?

It can be powered by battery or a continuous power accessory.

What is the enclosure material and rating?

Stainless steel, NEMA 4X, IP65.