This manual is a maintenance manual for the Talon Series Motor Truck Scale HV and HVX Series produced by Fairbanks Scales, mainly introducing the maintenance and installation of the scale
The Talon Series HV and HVX Motor Truck Scale service manual, document 51349 revision 14 dated 08/2021, covers modular steel and field-pour truck scales. It gives load cell and platform specifications, installation steps, foundation and module setting, and electrical wiring for analog instruments and Intalogix systems.
The manual also addresses scale maintenance, mechanical faults, load cell replacement, parts and hardware, recommended spare parts, and rub rail accessories. It is published by Fairbanks Scales Inc.
| Load cell capacity | 66,000 lbs; 110,000 lbs |
|---|---|
| Load cell type | 4 11/16 in stainless steel rocker column (RC cells) |
| Load cell material | Stainless steel |
| Load cell rating | NEMA 6P (IP68 / 69K) |
| Load cell operating temperature | -10 to +40°C (-14 to 104°F) |
| Platform widths | 10 ft, 11 ft, and 12 ft |
| Standard platform lengths | 10 ft to 120 ft |
| Scale capacity | 60 tons to 150 tons |
| Deck thickness | HV: 1/4 in plate; HVX: 3/8 in plate |
| Approval | NTEP CC# 96-089; MC# AM-4949 |
The stated operating temperature range is -10 to +40°C (-14 to 104°F).
The standard widths are 10 ft, 11 ft, and 12 ft.
Scale components must be located a minimum of thirty-six inches (36 inches) away from single and multiple phase high energy circuits and current-carrying conductors.
Standard lengths range from 10 ft to 120 ft.