ETCR 085K High-Precision Open/Close Leak Current Sensor User Manual

The ETCR 085K user manual describes the high‑precision open/close leak current sensor, its specifications, installation, and operation.


ETCR 085K High-Precision Open/Close Leak Current Sensor User Manual - cover page
Brand
ETCR
Category
Current Monitor
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
321 KB
Published
30 September, 2026
Updated
30 September, 2026
MD5 checksum
34F9003D7CACC20641560E12DB8DBD3E

About this manual

The ETCR 085K is a high‑precision open/close leak‑current sensor designed for power, communications, railway, oil‑field and other demanding environments. It measures AC leak current, total current, harmonic current, frequency, phase, power and energy with a four‑layer shielding design and waterproof protection.

The manual provides an introduction, technical specifications, principle of operation, installation directions, wiring details, safety standards and handling instructions. It also includes dimensions, environmental limits and recommended installation methods for wall‑mount or direct‑mount on flat‑steel grounding conductors. This manual is written in Chinese.

What's inside

  • Introduction
  • Technical Specifications
  • Principle and Structure
  • Installation Directions
  • Safety Standards

Specifications

Opening size85 mm × 20 mm
Shielding layers4 layers
Turns ratio1:1000
Input rangeAC 0.00 mA ~ 100.0 A
Accuracy±1.0 %FS
Operating temperature / humidity-20 °C ~ 50 °C, ≤80 % RH
Insulation strengthAC 3700 V rms

Frequently asked questions

What is the opening size of the ETCR 085K sensor?

The sensor’s opening size is 85 mm × 20 mm.

How should the sensor be oriented during installation?

Mount the sensor with the P1 side facing up and parallel to the ground.

What is the measurement accuracy of the sensor?

The sensor provides an accuracy of ±1.0 %FS.

Download PDF (321 KB)