Instructions for replacing the High Pressure Lock Off (HPLO) on the HPNGV4 Series Compressed Natural Gas Vehicle Regulator, including removal, assembly…
This manual provides step-by-step instructions for replacing the High Pressure Lock Off (HPLO) assembly on the HPNGV4 Series Compressed Natural Gas Vehicle Regulator. It details the necessary preparation steps, such as isolating the fuel supply and disconnecting the battery, to ensure safety during the repair process.
This repair kit includes all parts required to replace an HPLO on the NGV fuel pressure regulator.
The tower must be tightened to 25 +/- 2.5 ft-lb using a deep 6-point 7/8" socket wrench.
Apply 12 or 24 volts direct current power to the coil, depending on the model.