Installation and owner's manual for Empire Deluxe vent-free universal fireboxes, covering clearances, framing, gas connection, blower wiring and maintenance.
The Empire Comfort Systems Deluxe vent-free universal fireboxes are gas-fired and intended for use with listed gas-fired unvented decorative room heaters not exceeding 40,000 BTU/H. The manual lists models such as VFD32FB0F-4, VFD36FB0F-4, and VFD42FB0F-4.
It provides installation instructions, safety information, clearances, framing dimensions, hood installation, gas line connection, optional FBB5 blower and junction box wiring instructions, maintenance, parts, accessories, and warranty information.
| VFD32FB framing dimensions | 33 3/4 in height x 35 1/2 in width x 16 1/4 in depth |
|---|---|
| VFD36FB framing dimensions | 35 3/4 in height x 40 1/2 in width x 18 3/4 in depth |
| VFD42FB framing dimensions | 35 3/4 in height x 44 1/2 in width x 18 3/4 in depth |
| Maximum unvented room heater input | 40,000 BTU/H |
| Sidewall clearance | 6 inches minimum |
| Ceiling clearance | 42 inches minimum from top of hood |
| Grate clearance | 2 inches minimum |
| Front clearance | 36 inches minimum |
It is only for use with the type of gas indicated on the rating plate and is not convertible for other gases unless a certified kit is used.
It may be installed in an aftermarket, permanently located manufactured home (USA only) or mobile home where not prohibited by local codes.
The firebox is for use only with a listed gas-fired unvented decorative room heater not to exceed 40,000 BTU/H.
It should be inspected before use and at least annually by a qualified service person; more frequent cleaning may be required due to excessive lint.