Empire Comfort Systems Deluxe Vent-Free Universal Firebox Installation Instructions and Owner's Manual

Installation and owner's manual for Empire Deluxe vent-free universal fireboxes, covering clearances, framing, gas connection, blower wiring and maintenance.


Empire Comfort Systems Deluxe Vent-Free Universal Firebox Installation Instructions and Owner's Manual - cover page
Brand
Empire Comfort Systems
Category
Heater
Document type
Installation Guide
Language
English
Pages
20
File format
PDF
File size
1.4 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
9A422F80BC6FC8DB81461BF154EF0253

About this manual

The Empire Comfort Systems Deluxe vent-free universal fireboxes are gas-fired and intended for use with listed gas-fired unvented decorative room heaters not exceeding 40,000 BTU/H. The manual lists models such as VFD32FB0F-4, VFD36FB0F-4, and VFD42FB0F-4.

It provides installation instructions, safety information, clearances, framing dimensions, hood installation, gas line connection, optional FBB5 blower and junction box wiring instructions, maintenance, parts, accessories, and warranty information.

What's inside

  • Important Safety Information
  • Introduction
  • Clearances
  • Firebox Installation Instructions
  • Installing Hood
  • Gas Line Connection
  • Optional FBB5 Single Speed Blower Installation Instructions
  • Junction Box Wiring Installation Instructions
  • Maintenance
  • Parts List

Specifications

VFD32FB framing dimensions33 3/4 in height x 35 1/2 in width x 16 1/4 in depth
VFD36FB framing dimensions35 3/4 in height x 40 1/2 in width x 18 3/4 in depth
VFD42FB framing dimensions35 3/4 in height x 44 1/2 in width x 18 3/4 in depth
Maximum unvented room heater input40,000 BTU/H
Sidewall clearance6 inches minimum
Ceiling clearance42 inches minimum from top of hood
Grate clearance2 inches minimum
Front clearance36 inches minimum

Frequently asked questions

What gas can be used with the firebox?

It is only for use with the type of gas indicated on the rating plate and is not convertible for other gases unless a certified kit is used.

Can the firebox be installed in a mobile home?

It may be installed in an aftermarket, permanently located manufactured home (USA only) or mobile home where not prohibited by local codes.

What is the maximum input for a listed gas-fired unvented decorative room heater?

The firebox is for use only with a listed gas-fired unvented decorative room heater not to exceed 40,000 BTU/H.

How often should the appliance be inspected?

It should be inspected before use and at least annually by a qualified service person; more frequent cleaning may be required due to excessive lint.