This is an instruction manual that introduces the basic knowledge of installation and use of gas heater
This document provides installation instructions for Empire Comfort Systems' unvented gas log burners, including safety warnings, air shutter settings, gas pressure requirements, and accessory details. It covers models VFSR-(16,18,24,30)-4 and VFSM-(16,18,24,30)-3, with specifications for natural and propane gas. The guide emphasizes safety, proper ventilation, and correct installation to prevent fire or explosion hazards.
Installation steps include preparing the fireplace, installing gas lines, wiring, lighting the burner, and performing maintenance. The document also includes tables for air shutter settings and model-specific BTU ratings, as well as warnings about using the appliance only with the gas type indicated on the rating plate.
| Gas Valve Type | Millivolt or Manual |
|---|---|
| Regulator Pressure Setting (Natural Gas) | 3.5" W.C. |
| Max. Gas Inlet Pressure (Natural Gas) | 10.5" W.C. |
| Air Shutter Opening (Natural Gas Models) | 1/16" or 1/8" |
| Air Shutter Opening (LP Gas Models) | Fully Open |
This appliance is only for use with the type of gas indicated on the rating plate. It is not convertible for use with other gases.
For natural gas models, the air shutter setting must be 1/16" or 1/8".
For LP gas models, the air shutter setting must be "fully open."