Technical data sheet for EM TEST CNV 504/508 T-Series coupling/decoupling networks designed for unshielded symmetrical communication lines testing.
The EM TEST CNV 504 / 508 T-Series are coupling/decoupling networks designed for applying surge pulses and telecom surge pulses to unshielded symmetrical interconnection lines. These networks comply with IEC 61000-4-5 Ed.3 and ITU-T K.44 standards, featuring coupling via gas arrestors and built-in matching resistors. The series includes models for 4 lines (CNV 504T5) and 8 lines (CNV 508T5), supporting test voltages up to 5kV.
| Max. voltage impulse | 5 kV |
|---|---|
| Line voltage max. | 50 V |
| Line current max. | 1 A |
| Decoupling inductor | 20 mH |
| Signal Bandwidth | 100 kHz |
| Temperature range | 5 - 40 °C |
| Relative humidity | 10 - 90 % |
They comply with IEC 61000-4-5 Ed.3 and ITU-T K.44 standards.
The CNV 504T5 is designed for 4 lines (2 pairs), and the CNV 508T5 is for 8 lines (4 pairs).
The networks support test pulses of 1.2/50 - 8/20µs and 10/700µs.