User manual for Electrolux EWE241MX-DST2 electric water heater covering parts, controls, safety, installation, and electrical specs.
This user manual provides detailed instructions for installing and operating the Electrolux EWE241MX-DST2 electric water heater. It includes parts identification, LED display and control panel descriptions, safety warnings, installation procedures, and electrical loading specifications. The document also covers specific installation steps for Malaysia and notes on pump models, grounding requirements, and troubleshooting tips for common issues like overheating or ELCB tripping.
| Voltage | 220V ~ 50/60 Hz |
|---|---|
| Minimum Water Flow Rate | 2.0 litre/min |
| Maximum Working Pressure | 6 bars |
| ELCB Leakage Current | 15mA |
The minimum water flow rate is 2.0 litre/min to trigger the flow sensor.
The heater base should be mounted 1.5m above the bathroom floor.
Use 2.5mm² double insulation cable for 4.8kW models.