The Edbro 1SEC & 1LNC to 4LNC Hoist Operator's Manual provides safety guidelines, operation instructions, maintenance steps and parts information.
This operator's manual explains the correct use, safety code and operating pressure for the 1SEC & 1LNC to 4LNC electro‑hydraulic hoist. It includes identification details, familiarisation notes and a full safety checklist to help operators avoid accidents while tipping.
The guide also covers how to lift and lower the body, control operation, oil filling, routine maintenance and troubleshooting. A list of service locations and spare‑part ordering instructions is provided for quick support.
| Maximum operating pressure | 120 bar (1,750 psi) |
|---|---|
| Recommended hydraulic oil | ISO6734/4 HM32 for -20°C to +30°C |
| Maximum engine revs during lifting | 1100 rpm |
The hoist must not be operated above 120 bar (1,750 psi) as shown on the identification plate.
Use hydraulic oil that meets ISO6734/4 HM32 specifications, suitable for temperatures from –20 °C to +30 °C.
Check that the oil level is correct, the PTO is engaged, and the tipper lever is in the raise position; if it still does not stay up, lower the body and repeat the lift.
Do not exceed 1100 rpm when lifting the body.