This manual provides operating instructions, safety guidelines, installation steps, and maintenance procedures for the EA Elektro-Automatik EL 3000 B series…
This document is the user manual for the EA Elektro-Automatik EL 3000 B series of programmable DC electronic loads. It covers the product's intended use as a variable voltage source, current source, or electronic load, and details the safety precautions required for operation to prevent damage to the device or connected equipment.
The guide provides comprehensive instructions for installation, including unpacking, physical setup, and connecting various interfaces such as USB, LAN, and analog ports. It also explains the different operating modes (Constant Voltage, Constant Current, Constant Resistance, Constant Power) and how to configure the device via the front panel or remote control. This manual is written in Chinese.
| Display | Color TFT display, 480pt x 128pt |
|---|---|
| Control Interface | 2 knobs with push-button function, 7 buttons |
| Operating Temperature | 0-50 °C |
| Maximum Humidity | 80%, no condensation |
| Operating Altitude | Max 2000 m above sea level |
It can be used as a power supply or battery charger, and as an electronic load acting as a variable current absorption source.
The OT (OverTemperature) signal indicates that the product temperature is too high, which will close the DC input.
No, the manufacturer does not accept claims for damage caused by using the product for other purposes than designed.