This user manual covers safety, technical data, connections, functions, and interfaces for the EA-PS 9080-50 laboratory power supply.
The EA Elektro-Automatik EA-PS 9080-50 is a desktop laboratory power supply designed to replace numerous variants with high stability and extended functionality. It features a flexible output stage allowing for high voltage or current depending on the setting, limited by total power (1.2kW). The device can be configured as a table unit or converted for 19-inch rack mounting using an included kit.
The manual provides detailed instructions on safety precautions, including handling of voltages exceeding 60V DC and ESD protection. It describes various connection methods such as the rear terminal block, front panel safety sockets, sense connections, parallel operation via Share-Bus, series operation, and analog interfaces for external control. This manual is written in German.
| Input Voltage Range | 88...264V |
|---|---|
| Maximum Power (Derated) | 1200W |
| Dimensions | 460mm width, 2HE height |
No, the device cannot be repaired by the user and must only be opened by a qualified electrician.
For an output current of 100A, a cross-section of 2x 25 mm² should be used.
Yes, after shutdown due to high temperature, the device can automatically turn itself back on if the temperature returns to the permitted range.